Negotiable
The date of payment from buyers deliver within days
Beijing
Long-term effective
2023-08-27 09:09
165
Company Profile
KINGNEN Technology Co., Ltd.By certification [File Integrity]
Contact:kaixianxinneng(Mr.)
Email:
Telephone:
Phone:
Area:Beijing
Address:Beijing
Website:http://www.kingnenmeter.com/ http://kaixianxinneng.hilipc.com/
The PMC200S digital panel meter, which is a compact panel-mounted device for power measurement and control, is capable of integrating data acquisition and control functions. It can replace various instruments, relays, transformers, and other components by utilizing extended DI/DO and AI/AO modules, tailored to meet the specific requirements of various application scenarios.
Â
Based on the measurement of rms, the PMC200S, a panel-mounted instrument, is able to accurately measure highly nonlinear loads. It is now possible to precisely measure a variety of power parameters, including current/ voltage harmonics, energy, power factor, voltage/ current, frequency, and power.
In comparison to conventional energy meters, PMC200S is more portable, easy to use, and cost-effective. It can be used in a variety of applications, including energy management systems, substation automation, distribution networks, community power distribution, industrial power plants, intelligent buildings, smart distribution panels, high and low voltage switchgear, among others.
You can learn more about power load conditions, pinpoint peak energy consumption times, and implement targeted energy-saving strategies by using the PMC200S. More intelligent energy management is made possible by our product's 485 communication interface, which enables you to communicate with other gadgets and smart systems.
We are dedicated to providing you with comprehensive and dependable energy monitoring and management solutions that will assist you in meeting your energy-saving and emission-reduction objectives while boosting cost-effectiveness. When you choose our multifunctional meter, you will benefit from sophisticated technology, simple operation, and a long-lasting quality guarantee.
Â
Â
Instantaneous true RMS | |
Current | each single phase and conjunction, average |
Phase voltage/line voltage | each single phase and conjunction, average |
Active, reactive, apparent power | each phase and the sum of three phases |
Power factor | each phase and the sum of three phases |
Frequency | 45~65Hz |
Maximum/minimum value | |
Max/min rms current | |
Max/min rms phase voltage | |
Max/min total active, reactive, apparent power | |
Max/min total power factor | |
Max/min frequency | |
Max/min THD I and THD U | |
Demand and peak demand value | |
Current per phase | current value/peak/month end peak |
Total active, total reactive, total apparent power | current value/peak/month end peak |
Energy | |
Input/output/total active energy | 1 pulse output |
Input/output/total reactive energy | 1 pulse output |
Apparent electrical energy | |
Compound rate of electrical energy | |
8 recharge periods, 4 rates can be set | |
Power quality | |
Total Harmonic Distortion Rate (THD) | current and voltage |
1st-31st harmonic analysis | current and voltage |
Voltage peak coefficient CF and current K coefficient | |
Event logging | |
100 SOE event records | |
Alarm system | |
8 configurable limit alarm channels | |
4 configurable logical alarm channels | |
Communication | |
RS-485 /MODBUS-RTU protocol | |
Display | |
STN LCD display | |
Real-time clock | |
Year, month, day, minute, second | |
Other | |
Program online upgrade supported |
Â
Optional features |
Digital Input (DI) module (optional) |
4 switching inputs |
Digital Output (DO) module (optional) |
2 relay outputs, which can be set by local overrun alarm or controlled remotely |
Analog Input (AI)/Output (AO) module (optional) |
A total of 2 channels. Optional 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output |
Â
Â
Electrical characteristics | ||
System | Three-phase three-wire AC system, three-phase four-wire AC system; | |
Sample rate | 128 samples per cycle | |
Data refresh rate | 1s | |
Measurement accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active energy | 0.5S | |
Reactive energy | 1.0S | |
DC input (AI) | 0.5% FS | |
DC output (AO) | 0.5% FS | |
Voltage input | Measure voltage | 3*220/380V(Direct input) |
3*57.7/100V (PT secondary) | ||
Overload | 1.2x/continuous | |
Input impedance | 300KΩ | |
Current input | Measure current | 5A (CT secondary) or 1A (CT secondary) |
Overload | 1.2x/continuous | |
Input impedance | <0.1Ω | |
Digital input | Operating voltage | 12~24VDC |
Input impedance | 12KΩ | |
Isolation voltage | 2KV | |
Digital output | Node type | Mechanical contacts |
Node capacity | 220 VAC/5Aã€30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4~20mA |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure voltage | 0~5V |
Allowed overload capacity | 1.2x/continuous | |
Input impedance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit voltage | 15VDC |
Load capacity | ≤600Ω | |
Isolation voltage | 2KV | |
Working power supply | AC | 100~240VAC/45~65Hz |
DC | 100~375 VDC | |
power consumption | < 3W | |
Mechanical characteristic | ||
Weight | 0.5kg | |
IP protection rating | Instrument panel IP52, instrument body IP30 | |
Size | host | 96 *96 * 72 mm |
Host + module | 96 * 96 * 120 mm | |
Operating temperature | display | -20~70°C |
Instrument | -25~70°C | |
Storage temperature | instrument + display | -40~85°C |
Humidity | 5% ~ 90%RH, non-condensing | |
Electromagnetic compatibility | ||
Electrostatic discharge | IEC 61000-4-2,Level 4 | |
Fast transient | IEC 61000-4-4,Level 4 | |
Surges | IEC 61000-4-5,Level 3 | |
Magnetic fields | IEC 61000-4-8,Level 3 | |
Electrical insulation | ||
Insulation resistance | GB/T13729,>50MΩ | |
AC voltage | GB/T13729, AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
Â
The size of the instrument is shown below.
Â
Embed the meter into the 90mm*90mm cutout slot and screw on the fixing buckle.
Â
As displayed in the figure underneath, the instrument is in the assortment layer and is liable for the estimation and assortment of force information for each circle. Simultaneously, the instrument outfitted with DI/DO, computer based intelligence/AO modules can understand switch status observing, transfer yield, DC voltage and current information checking, and transmitter, which can likewise be modified to your determinations.
Â
Model code: PMC200S-(1)-(2)-(3)-(4)-(5). | |
(1)Input voltage and current: | |
1 | 57.7/100V rated measurement voltage, 5A rated measurement current. |
2 | 57.7/100V rated measurement voltage, 1A rated measurement current. |
3 | 220/380V rated measurement voltage, 5A rated measurement current. |
4 | 220/380V rated measurement voltage, 1A rated measurement current. |
(2)Power supply: | |
1 | Power supply: 85~264 VAC/45~65Hz, 100~300 VDC. |
(3)DI: | |
0 | No DI |
4 | 4-way DI |
(4)Optional: | |
0 | No optional |
1 | Optional 1 relay output (RL1+, RL1-port). |
2 | Optional 2 relay outputs |
(5)AI&AO: | |
ab | "a" is for selecting the AI/AO module for AIO1 port, and "b" is for selecting the AI/AO module for AIO2 port. The optional modules are: 0 - None 1 - 5V DC analog input measurement (AI) 2 - 420mA DC analog input measurement (AI) 3 - 4~20mA DC analog output (AO) For example, "ab = 00" means the AI/AO module is not selected for AIO1 port, and the AI/AO module is not selected for AIO2 port. "ab = 12" means the AIO1 port is equipped with the 5V DC analog input measurement module, and the AIO2 port is equipped with the 420mA DC analog input measurement module. |
Â
Kingnen Co., Ltd., a professional producer of intelligent measurement and control instruments and equipment for troubleshooting power systems, was founded in 2014. Our areas of expertise include independent production, sales, and R&D. Being a nationally recognized high-tech company, we hold the Shenzhen Double Soft Certification. Our firm occupies a 3,000 square meter manufacturing and 1,500 square meter office space at Building CD, Block 4, Tian'an Digital City, Shenzhen, China.
Â
We vow to give brilliant item quality confirmation and extensive after-deals administration support as concurred, guaranteeing your fulfillment. We ensure straightforward guarantee terms and will rigorously satisfy our authoritative commitments, permitting you to appreciate long haul guarantee benefits. During the concurred after-deals administration period, we offer free proficient types of assistance to address every one of your interests. Indeed, even after the help period, we will arrange sensible accuses of you to guarantee that you keep on getting excellent assistance without extra weights.
Â
1. Do expansion modules need to be used?
Although they are not required, input/output extension modules enable functionality like relay outputs, transmitters, DC voltage and current input monitoring, and switch status monitoring. Moreover, we may offer customisation in accordance with your particular needs.
Â
2. The number of PMC200S that can be set up on a single acquisition node?
A single node may support up to 32 devices when configured with a Category 5e shielded twisted pair cable. The overall bus length should not be more than 1200 meters in the absence of repeaters.
Â
http://www.kingnenmeter.com/