The ethylene glycol chiller is a kind of cooling water equipment with constant temperature and current and constant pressure. Its main function is to cool the liquid water inside the main engine to ensure a constant temperature. Nanjing RICOM glycol water cooler is divided into two types: screw type and vortex type.
The structure and composition of the glycol chiller are roughly the same, including compressor, evaporator, condenser, throttling element and electric control system. However, for the glycol chiller, it USES a low-temperature compressor and is equipped with economic separator and other components.
Product Principle
Product Characteristics
1. The mixed liquid of ethylene glycol has antifreeze function, which can avoid the freezing of circulating water in the use process under the condition of 0℃, and will not cause faults in the operation process.
2. Adopt low-temperature compressor, (more bipolar compressor can be refrigerated to -40 degrees temperature) reliable performance, built-in safety protection, low noise, power saving and durable
3. The compressor adopts original brand products, such as "German "BIZEER", Taiwan "HANBELL" screw type or American COPELAND compressor or Japan "PANASONIC", etc. to ensure stable operation of the machine.
4. Equipped with precision digital display temperature controller, digital display water temperature, can accurately control the water temperature ±1℃, set the temperature range of -40℃ -- 35℃;
5. High efficiency all-copper shell and tube condenser and evaporator.
Product Process
Nanjing RICOM Refrigeration Equipment Co., Ltd. adheres to the spirit of craftsmanship and creates high-quality products.
Product Parameters
Technical parameters of ethylene glycol water - cooled screw chiller | ||||||||
Model |
RC2-40WD |
RC2-50WD |
RC2-60WD |
RC2-80WD |
RC2-90WD |
RC2-100WD |
RC2-110WD |
|
Refrigerating capacity (Kcal/h) |
71294/82.9/23.6 |
93568/108.8/30.9 |
100534/116.9/33.2 |
134504/156.4/44.5 |
167442/194.7/55.4 |
186362/216.7/61.6 |
200724/233.4/66.4 |
|
Refrigerant |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
|
Compressor Power (Hp) |
40 |
50 |
60 |
80 |
90 |
100 |
110 |
|
Supply voltage |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
|
Energy regulation mode |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
|
Starting mode |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
|
Piping of cooling water system |
Pipe diameter |
3" |
3" |
3" |
3" |
4" |
4" |
4" |
Chilled drainage piping |
Pipe diameter |
3" |
3" |
3" |
3" |
4" |
4" |
4" |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ |
Model |
RC2-120WD |
RC2-140WD |
RC2-150WD |
RC2-160WD |
RC2-180WD |
RC2-200WD |
RC2-230WD |
|
Refrigerating capacity (Kcal/h) |
218268/253.8/72.2 |
265052/308.2/87.6 |
277092/322.2/91.6 |
306418/356.3/101.3 |
344602/400.7/113.9 |
401362/466.7/132.7 |
431978/502.3/142.8 |
|
Refrigerant |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
|
Compressor Power (Hp) |
120 |
140 |
150 |
160 |
180 |
200 |
240 |
|
Supply voltage |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
|
Energy regulation mode |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
|
starting mode |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
|
Piping of cooling water system |
Pipe diameter |
4" |
5" |
5" |
5" |
5" |
5" |
5" |
Chilled drainage piping |
Pipe diameter |
4" |
5" |
5" |
5" |
5" |
5" |
5" |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ |
Model |
RC2-240WD |
RC2-280WD |
RC2-300WD |
RC2-320WD |
|
Refrigerating capacity (Kcal/h) |
436536/507.6/144.4 |
530104/616.4/175.2 |
598130/695.5/197.8 |
682840/794/225.8 |
|
Refrigerant |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
|
Compressor Power (Hp) |
240 |
280 |
300 |
320 |
|
Supply voltage |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
AC380V50HZ3PH/ |
|
Energy regulation mode |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
25%-50%-75%-100% |
|
starting mode |
Y/▲ |
Y/▲ |
Y/▲ |
Y/▲ |
|
Piping of cooling water system |
Pipe diameter |
5" |
6" |
6" |
6" |
Chilled drainage piping |
Pipe diameter |
5" |
6" |
6" |
6" |
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ |
Technical parameters of ethylene glycol water-cooled scroll chiller | |||||||
Model |
SCW-05D |
SCW-08D |
SCW-10D-Ⅱ |
SCW-15D-Ⅲ |
SCW-20D-Ⅱ |
SCW-30-Ⅱ |
|
Refrigerating capacity (Kcal/h) |
7740/9/2.6 |
11911/13.85/4 |
16340/19/5.4 |
23908/27.8/7.9 |
32680/38/10.8 |
47816/55.6/15.8 |
|
Refrigerant |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
R22/R134A/ |
|
Compressor power (Hp) |
5 |
8 |
10 |
15 |
20 |
30 |
|
Circulating pump power (Hp) |
1 |
2 |
2 |
3 |
3 |
4 |
|
Piping of cooling water system |
Pipe diameter |
1" |
1.5" |
1.5" |
2" |
2" |
2.5" |
Flow (m³/h) |
3.4 |
5.5 |
6.85 |
9.3 |
12.7 |
18.5 |
|
Chilled drainage piping |
Pipe diameter |
1" |
1.5" |
1.5" |
2" |
2" |
2.5" |
Flow (m³/h) |
2.74 |
4.27 |
4.27 |
8.59 |
8.59 |
14.55 |
|
Supply voltage |
AC380V50HZ3PH |
AC380V50HZ3PH |
AC380V50HZ3PH |
AC380V50HZ3PH |
AC380V50HZ3PH |
AC380V50HZ3PH |
|
Refrigerating capacity is based on evaporation temperature of 7℃, condenser temperature of 40℃, refrigerant: R22, and cooling water temperature of 32-37℃ |
Customer Case
Ethylene glycol chiller is widely used in rubber, plastics, petroleum, chemical industry, electronics, papermaking, textile, brewing, pharmaceutical, food, machinery, beverage, vacuum coating, electroplating, central air conditioning and many other fields. At the same time, it is also widely used in the centralized cooling way to facilitate the centralized pipe. The cryogenic chiller can be customized to meet the special requirements of customers' special technology, or the cryogenic chiller can be customized to meet the special requirements of customers' special technology.
My company has served many industries, has a wealth of industry application experience.
FAQ
Common problems when buying products
Q: How long has your company been established?
A: Our company was founded in 2014, but most of our engineers have been in the industry for over 15 years, and our boss has been in the industry for over 20 years.
Q: Is your company a trading company?
A: Our company is a trading company, but we have our own factory.
Q: What are your terms of payment?
A:T/T pays 30% in advance and 100% before delivery.
Q: How long is your delivery time?
A: 25-30 working days for standard products and 45 working days for non-standard customization
Q: How long is the warranty?
A: If the parts are broken or damaged, within 18 months from the date of leaving the factory.
These parts are provided free of charge by our company (except for wearing parts due to quality problems).
Q: What should be paid attention to in daily maintenance of glycol chiller?
A: 1. Ensure the normal working voltage stability to provide a stable foundation for the operation of the chiller.
2. Take care to protect the water pump, and do not run the chiller under the condition of no water, so as to avoid the failure of circulating water pump of the glycol chiller unit.
3. Ensure the inlet and outlet channels of the chiller are smooth. It is recommended to clean the filter screen regularly to avoid blockage of the ash layer.
4. When the water temperature is raised or the water pipe cooler is kept warm, so as to avoid condensation water when the water temperature is lower than the ambient temperature, which is not conducive to the operation of the chiller.
http://www.oem-chiller.com/